This study focuses on improving the thermal comfort in Mosques in Iraq. Omar bin Abdul Aziz Mosque in Baghdad is taken as a case study. In general, the weather in Baghdad is hot- dry climate during the summer. the study was conducted at the time of noon prayer on Friday where the maximum number of people can be obtained inside the Mosque about 500 worshipers and severe environmental conditions. Numerical methods (CFD) are used for the simulation utilizing the package of ANSYS (FLUENT V. 18). As the results depending on the number of elements, 4 millions elements are used for dividing the physical domain. Thermal comfort was assessed by finding the values of the predicted mean vote (PMV), predicted percentage of dissatisfied (PPD), and ASHRAE standard-55. The adaptive redistribution of the air conditioning device strategy at five cases is used to obtain the best thermal comfort. Moreover, changing the angle of air intake of space by changing the angle inclination of the access blade at three different angles of 0o, 7.5o and 15o degree, and studying its effect on the thermal comfort in breathing level. The four case is the best in terms of thermal comfort when the angle of intake air at 0o.when the PMV was 0.35 and PPD is 7.5, which is lower than the original state. The improving percentage of PPD is 10 % and PMV 14 %.
The present study was concerned with the analysis, simulation of the air flow pat-terns and thermal comfort levels in the University of Anbar at conferences hall (Ibn Al Haitham hall). The study was performed in a hot - dry season. The pur-pose of the present work was to investigate the level of thermal comfort and the influence of the air flow on the flow patterns at the conferences hall. It has been assumed that the total number of occupying audiences in the hall was approxi-mately 100 persons. The present work simulated and analyzed four hypothetical cases, namely: in the first case, the hall was assumed as an empty place, whereas the other three cases were performed by redistribution for the three units of air conditioning, the hall was assumed as a filled place with persons in September 2019. The study was accomplished using simulation techniques, a CFD code (FLUENT 6.2) v.17, which is commercially available. The CFD modelling tech-niques were applied to solve the continuity, momentum and the energy conserva-tion equations in addition to the Turbulence k-є (RNG) model equations for a tur-bulence closure model. Thermal comfort was assessed by finding the values of predicted mean vote (PMV), predicted percentage of dissatisfied (PPD), and ASHRAE standard-55. In conclusion, the second case was the superior in compar-ison to these other cases. It was noted that the PMV value was 0.17, whereas the PPD value was 6.79 at the breathing level.
Reducing energy consumption and to ensure thermal comfort are two important considerations in designing an air conditioning system. The control strategy proposed is fuzzy logic controller (FLC).This paper describes the development of an algorithm for air condition control system based on fuzzy logic (FL) to provide the conditions necessary for comfort living inside a building.Simulation of the controlling air conditioning system, on which the strategy is adopted, was carried out based on MATLAB This system consists of two sensors for feedback control: one to monitor temperature and another one to monitor humidity. The controller i.e. FLC was developed to control the compressor motor speed and fan speed in order to maintain the room temperature at or close to the setpoint temperature.