New composite reinforced concrete beams, in which reinforced concrete component is connected to steel T-section, are proposed. The shear connection between the two components, the reinforced concrete and the T-section, is provided by the stirrups that are required for the reinforced concrete component to resist the applied shear. Experimental tests in addition to numerical analysis were conducted to determine the behaviour and strength of such beams under pure torsion. Full scale one conventional reinforced concrete beam, T1, and two composite reinforced concrete ones, T2 and T3, were tested. The degree of shear connection between the two components of beams T2 and T3 was changed by varying the number of stirrups which are used as shear connectors. The experimental results revealed approximately same torsional stiffness for the three beams at the uncracked concrete stage. The torsional strength of the composite reinforced concrete beams was greater than that of ordinary reinforced concrete one by 11% and 27% for beams T2 and T3, respectively. Three-dimensional finite element analysis was conducted using program ABAQUS. To model the shear connection in composite reinforced concrete beam, the stirrups were connected to the web of the steel T-section by springs at the location of the stirrups. Good agreement is obtained between the results of the experimental tests and the finite element analysis. The ratios of experimental results to those of finite element analysis for torsional strength are approximately one. Under the pure torsion loading the degree of shear connection is found to have no effect on torsional capacity of beams.
The behaviour of high-strength fiber reinforced concrete columns was observed with a testing program of 7 columns, loaded eccentrically. The theory was analyzed by modifying the stress block diagram of concrete. The experimental results show that using high-strength fiber reinforced concrete with fiber volume fraction of 1.0%, increased the column ultimate capacity up to 40% in addition to increasing its ductility and toughness, significantly. The proposed theoretical analysis gave a good estimation of experimental results.
The corrosion of reinforcement iron is one of the dangerous problems in middle and west of Iraq and Arabian gulf which is needed to large investigations because of increasing of chloride salts in soil and ground water and rising of temperature at summer which encourage of finding the shrinkage cracks in their two types : Plastic and drying shrinkage . cracks are easy way for harmful ions present at soil and ground water to enter through reinforced concrete making damage for protection film a rounding rein forced iron and led to rust with cracks in concrete cover a rounding rein forced iron added to its may be to cause structural damage in members of rein forced concrete because of absence of a adhesive between concrete and steel leading to structural failure . This research presents study for this problem and knowing their causes and methods to reduce it. Experimental work show that the concrete exposed to chlorides leads to decreasing in density with ratio (1.5%) and decreasing in flextural strength with ratio (138%) at age (28) day .
Deep beams with rectangular cross-sections are widely used in concrete structures. In the present study, reinforced concrete rectangular deep beams cast with self-compacted concrete (SCC) which contains recycled concrete as coarse aggregate (RCA) were tested under directly and indirectly loading conditions. In the experimental work, fifteen deep beams were investigated, the first parameter considered in this study was the shear span to effective depth (a/d) ratio. The other variable is the replacement ratio by which the normal coarse aggregate is replaced by RCA. The beams were cast without the use of shear reinforcement. During the tests, the response of the beams including the cracking load, the ultimate load, concrete strain, and mid-span deflection were recorded. Test results indicate that the presence of RCA caused a reduction in the values of cracking and ultimate loads. For instance, the cracking load was reduced by 9%, 23%, and 50% and the ultimate load was reduced by 2% , 23%, and 25% as RCA replacement increased by 25%, 50%, and 75% respectively for a/d ratio equals 1.0. Further, by increasing the a/d ratio, the ultimate load was decreased due to the lower contribution of arch action shear transfer in the beam with a higher (a/d) ratio.
This study aims to examine the relationship between the corrosion rate of longitudinal tensile steel bars and the maximum flexural strength of reinforced concrete RC beams. The study's methodology is designed to show the structural behavior of corroded and non-corroded RC beams, such as ultimate load, deflection, stiffness, crack patterns, and failure mode. Three rectangular beams were cast with dimensions (150× 200 ×1200) mm, and all specimens have the same amount of longitudinal and transverse reinforcement and the same concrete strength. The major parameter is the theoretical mass loss level due to corrosion (0, 10, 15) %. Electrochemical technique was used to accelerate the corrosion in the longitudinal tensile bars. All RC beams were tested under four-point monotonic loading. The test results confirm that the cracking load in corroded beams decreased by 25% comparative to the non- corroded beam. The increase of the percent of corrosion experimental mass loss by 8.25 and 14.15 % decreased the ultimate load by about 14 % and 27%, respectively. This reduction coincided with the decrease in deflection values in mid-span for the ultimate load, which decreased by 53.9% and 46.3%. However, the flexural stiffness was reduced by 13.4 and 15.6% for corroded beams with mass loss (8.25 and 14.15), respectively, compared to the control beam (non-corroded RC beam).
This paper presents a nonlinear finite element analysis of reinforced concrete beams subjected to pure torsion. A verification procedure was performed on three specimens by finite element analysis using ANSYS software. The verification with the experimental work revealed a good agreement through the torque-rotation relationship, ultimate torque, rotation, and crack pattern. The studied parameters of strengthening by CFRP sheets included strengthening configurations and number of CFRP layers. The confinement configuration methods included full wrapping sheet around the beam, U-shaped sheet, ring strips spaced at either 65 or 130 mm, longitudinal strips at the top and bottom faces, U-shaped strips in addition to the number of layers variable. It was found that the performance of the beam for resisting a torsional force was improved by (33-49%) depending on the method of coating with CFRP sheets and the number of used layers. A change in the angle of twist, as well as the shape of the spread of cracks, was also noticed from the predicted results.
Progressive collapse is a partial or total failure of a building that mostly occurs when the build-ing loses primary structural elements (typically columns) due to accidental or natural hazards. The failure of structures due to an earthquake is one of the most important and frequent types of progressive collapse. In this study, the finite element method is used to assess the response of multistory reinforced concrete buildings subjected to column loss during an earthquake. Three-dimensional nonlinear dynamic analyses are carried out using SAP2000 V.20 program. The ef-fects of different parameters on the progressive collapse behavior are investigated, namely: the location of the removed column within the ground floor; the method of column removal (sudden, in two-steps, and in four-steps) and the removal timing during the earthquake. It is demonstrated that the collapse occurs when all or most of the hinges at the bases of the ground floor columns reach their collapse level. The chosen column removal timing and policy affect the structural behavior considerably. It is realized that, the risk of building collapse increases when the removal timing harmonizes with the peak ground acceleration timing. Based on the adopted earthquake characteristics and building configurations, it is found that, the two steps removal scenario is the most dangerous one.Keywords:Progressive collapse, Concrete buildings, Seismic load, Nonlinear dynamic analysis, Plastic hinge.© 2014
This research investigates the impact resistace of reinforced high strength concrete slabs with steel meshes (BRC) modified by styrene butadiene rubber (SBR) with different weight ratios of polymer to cement as follows: 3%, 5% and 7%. Reference mix was produced for comparison of results. For all selected mixes, cubes (100×100×100mm) were made for compressive strength test at (365) days. In conducting low-velocity impact test, method of repeated falling mass was used: 1400gm steel ball falling freely from height of 2400mm on reinforced panels of (50×50×800 mm) reinforced with one layer of (BRC). The number of blows causing first crack and final perforation (failure) were calculated, according to the former results, the energy of each case was found. Results showed an improvement in compressive strength of polymer modified high strength concrete (PMHSC) over reference mix; the maximum increase being of it were (3.93%-11.96%) at age of (365) days. There is significant improvement in low-velocity impact resistance of all polymer modified mixes over reference mix. Results illustrated that polymer modified mix of (3%) give the its higher impact resistance than others, the increase of its impact resistance at failure over reference mix was (154.76%) while, for polymer modified mix (5%) it was (30.95%) and it was (14.28%) for polymer modified mix of (7%).
The main purpose of this search is to study the punching shear behavior of fourteen specimens of Reactive Powder Concrete (RPC) two-way flat plate slabs, half of these slabs have been exposed to a high temperature up to 400 C° by using an electric oven. All slabs have dimensions of (400x400x60) mm, with steel reinforcement mesh of (Ø6mm) diameter. Laboratory tests show that there is an increase in the value of First Crack Loading (FCL) and Ultimate Load (UL) by (208, and 216.67) % and a decrease in deflection by (56.85) % due using slab with complete reactive powder relative to a slap made of normal concrete. The use of the (RPC)mixture in layers in slabs gave results close to the slab which consists of full (RPC) this gives the benefit of more than the use of a slab that contains full reactive powder concrete in terms of cost, the increase was in FCL and UL by (130.8, 169.23, 102.7 and 135.135) % and a decrease in the value of deflection by (37.17, 47.64) %. The use of a partial reactive powder mixture also showed good results, and by increasing the dimensions of the RPC area, the results were better. the increase in FCL and UL by (54, 116, and 185) % and (53, 116.67, and 166.67) % and a decrease in value of deflection by (36.12, 42.4, and 50.26) % from reference slab. When slabs are subjected to high temperatures, there may be a decrease in the value of the FCL and UL and an increase in the value of deflection when compared to models not exposed to high temperature. But when compared to the reference slab with the same circumstance showed an increase in the value of the FCL and the rate ranged between (50- 200) % and the UL was the ratio ranged between (51.35-208.1) % and a decrease in the value of the deflection where the ratio ranged (21-46) %
This paper presents the experimental results of composite slabs under static and impact loading. Total of six specimens classified one specimen test under static loading and the remaining five were tests under impact dynamic loading with different parameters as type of connections and degree of interaction of composite slab. Low - velocity impact test was adopted by select the falling mass (4 kg) made from steel material and formed as ball shape without nose. The ball dropped freely from height of (2.4 m) and strikes the top of composite slab. The designed dimensions of specimens is (500×500×60 mm) as reinforced concrete slab that reinforced by mesh of (RBC) and the steel plate is (3 mm) in thickness. Deflection due to first crack is recorded, number of blows caused first crack and failure were counted. The test results showed that the welded stud connectors gives high strength capacity and resistance under static and impact dynamic loadings than other than type of connections, also, full interaction as degree of interaction is better than others
The status of the infrastructure of the transport system and then mobility in the governorate of Anbar is deplorable. Therefore, it requires two types of solutions in two phases. This study concerned with the first phase, which is represented by solving the problem of the inadequacy infrastructure in terms of availability between the cities, and work to develop it toward being maximally connected. So, generally speaking this study aimed to facilitate mobility through this network, by improving the accessibility in term of connectivity. The analysis process in this study, have twin objectives: first, to determine how much new linkages we need for our network to be maximally connected as a first stage? Second, Building a legislative framework lends the weight for decision makers in transport agency to take tough decision built up on ranking the new proposed linkages according to their relative values in providing access to the network, and the increment in comparable nodal accessibility due to the new additions. So, there is need for more sensible decisions based on more accurate analysis for deciding the optimum priorities for the new linkages to take place in the stage of development implementation via legislative framework. Therefore, the analysis will deal with topological characteristics for a number of aspects by expressing the simple graph of the network in a matrix format. These aspects are simulated and measured through the matrices powering process and the principles of graph theory. However, in addition to reducing the time the vehicles stays on the road, the study results will assist to divert a large proportion of the traffic volumes concurrently with the implementation process, and this in turn will pave the way to precede the solution of the second phase inside the cities. Not to mention, the legislative framework will bases for the financial framework of the transport agency. Keywords: infrastructure inadequacy& development, accessibility and connectivity, graph theory, matrix representation &powering, new linkage, nodal accessibility , relative value ,optimum priorities (ranking) and Decision making(legislation).
The demand for strengthening structures becomes necessary when an increase in load is inevitable. For instance very little information is available on the time-dependent behaviour of strengthened concrete columns. Also, this is a primary factor hindering the widespread uses of FRP strengthening technologies in the construction implementations. This paper investigates the behaviour of strengthened concrete columns with FRP sheets subjected to long-term loading by non linear finite element analysis using ANSYS computer package. A three-dimensional finite element model has been used in this investigation. This study achieved a good agreement between numerical and experimental results, it was found that the percentage of error of specimens do not pass (5%) for creep strain. In addition, a parametric study was performed to study the effect of different factors on the behaviour of FRP strengthened concrete columns.
This paper investigates the possibility of strengthening Reinforced Concrete (RC) beams under pure torsion loadings. The torsional behaviour of strengthened RC beams with near-surface mounted steel and CFRP bars was investigated. The verification with the experimental work was performed to ensure the validity and accuracy which revealed a good agreement through the torque-rotation relationship, ultimate torque, and rotation, and crack pattern. This numerical study included testing of thirteen specimens (one of them was control beams while the remaining 12 were strengthened beams) with several parameters such as mounting spacing and configuration. The analytical results revealed that the addition of NSM rebar redistributed the internal stresses and enhanced the ultimate torsional strength, torque-rotation capacity, ductility, and energy absorption of the concrete beams. Most of the strengthened beams revealed the appearance of the cracks at a phase less than the reference beam by an average of (9%). Concerning the NSM strengthening, the CFRP bars provided a higher enhancement ratio when compared with the beams that strengthened with NSM steel rebar especially for the strengthening space equal to 130 mm and more. The ultimate torsional strength increased by (3.5%) and rotation decreased by (4%) approximately when the steel rebar was replaced by the carbon bar. The ductility and energy absorption of the analysed beams showed that the strengthening enhanced the ductility of the twisted beams. The ductility values varied according to the method of strengthening used, as it showed the highest values of the beam that was strengthened small spacing.
The nonlinear finite element analysis has become an important tool, for the structural design and assessment of prestressed reinforced concrete members. However, design and assessment of torsion are still done with simplified analytical or empirical design methods. This paper pre-sents results from a numerical analysis using the ANSYS finite element program to simulate a prestressed concrete beams subjected to static and cyclic torque. The eight- node brick ele-ments SOLID65 are used for the idealization of concrete while the reinforcements are idealized by using 3D spar element LINK8. The steel plates are idealized by using three dimensional solid elements SOLID45. The results showed that the general behavior of the finite element models represented by torque- twist angle relationships show good agreement with the experimental results from the Abdullah's beams.